- comp_nameThe name of the components in the salt
C++ Type:std::vector<std::string>
Unit:(no unit assumed)
Controllable:No
Description:The name of the components in the salt
- comp_valThe mole fraction of each salt component
C++ Type:std::vector<double>
Unit:(no unit assumed)
Controllable:No
Description:The mole fraction of each salt component
- prop_def_fileDefinition of a fluid property file, which must be a file path to the comma-separated data matching the Saline format.
C++ Type:std::string
Unit:(no unit assumed)
Controllable:No
Description:Definition of a fluid property file, which must be a file path to the comma-separated data matching the Saline format.
SalineMoltenSaltFluidProperties
To use this object, you need to have the Saline
library installed. Refer to the documentation for guidance on how to enable it. (Original description: Molten salt fluid properties using Saline)
The mole fractions of the various elements / molecules present in the salt must sum to one. The following properties can be computed:
density
isobaric specific heat
enthalpy
viscosity
thermal diffusivity
Saline must be installed alongside MOOSE using the contrib/saline
submodule in the Fluid Properties module to be able to use this fluid property object. To initialize/download the Saline submodule:
Example input syntax
In this example, the fluid properties for a LiF-NaF-KF
salt mixture are computed by a SalineMoltenSaltFluidProperties
.
It leverages the salt property input data in the saline_custom.prp
file below. The data is sorted in columns. The first column is the name of the salt, then its id, then a number of thermo-physical properties with additional metadata such as the range of validity, the uncertainty and a short name for the reference publication providing the data.
More details on working with Saline can be found in this reference.
Input Parameters
- execute_onTIMESTEP_ENDThe list of flag(s) indicating when this object should be executed. For a description of each flag, see https://mooseframework.inl.gov/source/interfaces/SetupInterface.html.
Default:TIMESTEP_END
C++ Type:ExecFlagEnum
Unit:(no unit assumed)
Controllable:No
Description:The list of flag(s) indicating when this object should be executed. For a description of each flag, see https://mooseframework.inl.gov/source/interfaces/SetupInterface.html.
- prop_getter_suffixAn optional suffix parameter that can be appended to any attempt to retrieve/get material properties. The suffix will be prepended with a '_' character.
C++ Type:MaterialPropertyName
Unit:(no unit assumed)
Controllable:No
Description:An optional suffix parameter that can be appended to any attempt to retrieve/get material properties. The suffix will be prepended with a '_' character.
- use_interpolated_stateFalseFor the old and older state use projected material properties interpolated at the quadrature points. To set up projection use the ProjectedStatefulMaterialStorageAction.
Default:False
C++ Type:bool
Unit:(no unit assumed)
Controllable:No
Description:For the old and older state use projected material properties interpolated at the quadrature points. To set up projection use the ProjectedStatefulMaterialStorageAction.
Optional Parameters
- T_initial_guess400Temperature initial guess for Newton Method variable set conversion
Default:400
C++ Type:double
Unit:(no unit assumed)
Controllable:No
Description:Temperature initial guess for Newton Method variable set conversion
- p_initial_guess200000Pressure initial guess for Newton Method variable set conversion
Default:200000
C++ Type:double
Unit:(no unit assumed)
Controllable:No
Description:Pressure initial guess for Newton Method variable set conversion
- tolerance1e-08Tolerance for 2D Newton variable set conversion
Default:1e-08
C++ Type:double
Unit:(no unit assumed)
Controllable:No
Description:Tolerance for 2D Newton variable set conversion
Variable Set Conversions Newton Solve Parameters
- allow_duplicate_execution_on_initialFalseIn the case where this UserObject is depended upon by an initial condition, allow it to be executed twice during the initial setup (once before the IC and again after mesh adaptivity (if applicable).
Default:False
C++ Type:bool
Unit:(no unit assumed)
Controllable:No
Description:In the case where this UserObject is depended upon by an initial condition, allow it to be executed twice during the initial setup (once before the IC and again after mesh adaptivity (if applicable).
- allow_imperfect_jacobiansFalsetrue to allow unimplemented property derivative terms to be set to zero for the AD API
Default:False
C++ Type:bool
Unit:(no unit assumed)
Controllable:No
Description:true to allow unimplemented property derivative terms to be set to zero for the AD API
- control_tagsAdds user-defined labels for accessing object parameters via control logic.
C++ Type:std::vector<std::string>
Unit:(no unit assumed)
Controllable:No
Description:Adds user-defined labels for accessing object parameters via control logic.
- enableTrueSet the enabled status of the MooseObject.
Default:True
C++ Type:bool
Unit:(no unit assumed)
Controllable:Yes
Description:Set the enabled status of the MooseObject.
- execution_order_group0Execution order groups are executed in increasing order (e.g., the lowest number is executed first). Note that negative group numbers may be used to execute groups before the default (0) group. Please refer to the user object documentation for ordering of user object execution within a group.
Default:0
C++ Type:int
Unit:(no unit assumed)
Controllable:No
Description:Execution order groups are executed in increasing order (e.g., the lowest number is executed first). Note that negative group numbers may be used to execute groups before the default (0) group. Please refer to the user object documentation for ordering of user object execution within a group.
- force_postauxFalseForces the UserObject to be executed in POSTAUX
Default:False
C++ Type:bool
Unit:(no unit assumed)
Controllable:No
Description:Forces the UserObject to be executed in POSTAUX
- force_preauxFalseForces the UserObject to be executed in PREAUX
Default:False
C++ Type:bool
Unit:(no unit assumed)
Controllable:No
Description:Forces the UserObject to be executed in PREAUX
- force_preicFalseForces the UserObject to be executed in PREIC during initial setup
Default:False
C++ Type:bool
Unit:(no unit assumed)
Controllable:No
Description:Forces the UserObject to be executed in PREIC during initial setup
- fp_typesingle-phase-fpType of the fluid property object
Default:single-phase-fp
C++ Type:FPType
Unit:(no unit assumed)
Controllable:No
Description:Type of the fluid property object
- use_displaced_meshFalseWhether or not this object should use the displaced mesh for computation. Note that in the case this is true but no displacements are provided in the Mesh block the undisplaced mesh will still be used.
Default:False
C++ Type:bool
Unit:(no unit assumed)
Controllable:No
Description:Whether or not this object should use the displaced mesh for computation. Note that in the case this is true but no displacements are provided in the Mesh block the undisplaced mesh will still be used.